Pulse Oximeter,OLED Display Oxygen Monitor Fingertip,Blood Oxygen Saturation Monitor(SpO2) with Carrying Case,Silicone Cover

Add your review

$29.99

$29.99


Note: Prices may fluctuate as sellers adjust them regularly. You'll see the latest price at final checkout.
Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare


From the brand

AMEMO: In the name of love, we protect every home.

In the fast-paced modern life, health has become the most precious asset for everyone. However, our busy lives often make us neglect our physical well-being. It is with this insight that AMEMO was born, determined to become an indispensable guardian of health in every household.

Amemo Pulse Oximeter

Product Dimensions ‏ : ‎ 2.2 x 1.25 x 1.2 inches; 3.21 ounces
Batteries ‏ : ‎ 2 AAA batteries required. (included)
Date First Available ‏ : ‎ January 8, 2020
Manufacturer ‏ : ‎ SHENZHEN AEON TECHNOLOGY CO.,LTD
ASIN ‏ : ‎ B083NPD8Z7
Best Sellers Rank: #125,466 in Health & Household (See Top 100 in Health & Household) #101 in Athletic & Aviation Pulse Oximeters
Customer Reviews: 4.7 4.7 out of 5 stars 7,239 ratings var dpAcrHasRegisteredArcLinkClickAction; P.when(‘A’, ‘ready’).execute(function(A) { if (dpAcrHasRegisteredArcLinkClickAction !== true) { dpAcrHasRegisteredArcLinkClickAction = true; A.declarative( ‘acrLink-click-metrics’, ‘click’, { “allowLinkDefault”: true }, function (event) { if (window.ue) { ue.count(“acrLinkClickCount”, (ue.count(“acrLinkClickCount”) || 0) + 1); } } ); } }); P.when(‘A’, ‘cf’).execute(function(A) { A.declarative(‘acrStarsLink-click-metrics’, ‘click’, { “allowLinkDefault” : true }, function(event){ if(window.ue) { ue.count(“acrStarsLinkWithPopoverClickCount”, (ue.count(“acrStarsLinkWithPopoverClickCount”) || 0) + 1); } }); });
✅【As precise as specialized medical apparatus】This oximeter features a medical-grade sensor made in Japan, a high-speed processor, and intelligent algorithms to ensure that the measurement results are as accurate as those from professional instruments used in hospitals. Please refer to the introduction video of this oximeter for a demonstration comparing its oxygen saturation monitoring results with those of professional medical testing equipment.
✅【Industrial-Grade Reliability】This oximeter is manufactured using industrial-grade materials and processes, ensuring exceptional durability. It has been tested for resilience against drops from heights, water immersion, and extreme temperatures, yet it continues to function properly. Please refer to the durability test demonstration video in the introduction video of this oximeter.
✅【Seeing is Believing】The introduction video of this pulse oximeter includes actual comparative test demonstrations and destructive test demonstrations showcasing its accuracy, durability, speed, and continuous monitoring alarm features. Seeing is believing, ensuring you can purchase a reliable product.
✅【Continuous Monitoring】This pulse oximeter features a special spring-clip design combined with internal medical grade silicone material, ensuring it stays in place. The oximeter can continuously monitor blood oxygen levels and heart rate during exercise or while sleeping. Please refer to the clip stability demonstration in the introduction video of this pulse oximeter.
✅【Alarm Function】This pulse oximeter allows you to set alarm values for blood oxygen and heart rate. It will emit an alarm if the heart rate or blood oxygen levels are abnormal during exercise or sleep. It can be used for continuous monitoring during exercise or while sleeping.
✅【Larger & Brighter Screen】The blood oxygen saturation monitor features a 1.2-inch OLED display, larger than other 0.9-inch screens, with higher brightness and more vivid colors, ensuring that the elderly can easily read measurement data.
✅【One-Key Setup】This oximeter only requires one button to set the blood oxygen/heart rate alarm thresholds. 【Setup Method】 Press the fingertip button on the oximeter to turn it on, then long-press the button for 2 seconds to enter the settings page. Important Note: Long-press for 2 seconds to go to the next page or make a setting; short-press to move to the next item. Refer to the Setup Demo in the introduction video of this pulse oximeter.
✅【Visual Data, Fast Measurement, Auto Shutdown】The pulse oximeter fingertip provides real-time readings: blood oxygen saturation (SpO2), pulse rate per minute (PR), pulse intensity level (PI), pulse waveform indicator, pulse indicator, and battery level. Under normal circumstances, the oximeter can provide test results for blood oxygen and heart rate in as little as 3 seconds.
✅【Packaging Contents & After-Sales Service】The package includes a pulse oximeter, carrying case, two batteries (please refer to the positive and negative indicators for correct battery installation), lanyard, and user manual. –If you have any questions, please feel free to contact us via Amazon Messaging at any time.

8 reviews for Pulse Oximeter,OLED Display Oxygen Monitor Fingertip,Blood Oxygen Saturation Monitor(SpO2) with Carrying Case,Silicone Cover

0.0 out of 5
0
0
0
0
0
Write a review
Show all Most Helpful Highest Rating Lowest Rating
  1. joanieh

    simple to use, love the case too
    This is a great item for all households. Easy to use and know what your oxygen level is. My husbandhas heart problems and takes his blood pressure daily. He can also use this in addition. Like the caseit comes in too, thanks!

    Helpful(0) Unhelpful(0)You have already voted this
  2. Abbe

    A useful conventional pulse oximeter for non-medical purposes
    TL ; DNR- model A310 of OEM manufacturer Aeon Technology ;- FDA-cleared dual probe (red/near-IR) pulse oximeter ;- has EU’s CE mark and a TÜV SÜD’s certification for it ;- has ± 3% RMS-error accuracy & 1% SpO2 resolution ;- acceptable precision of 2% or less repeatability error ;- minimum 25-30 sec measuring time for reliable data.__# 1. UPDATE (July 2022). Before the start of the CoV2 pandemic, I got this device to monitor the amount of oxygen carried by my red blood cells when at 1500m or more, elevations at which not only the reduction of oxygen’s partial pressure starts to affect my body, but also can take a long time to adjust to it when coming from ~300ft above sea. Nevertheless, with the pandemic’s arrival, the device had a steady routine use at home over the last two and a half years with no issues. For mountaineering purposes, it has been tested on a Pic Aneto’s couloir gig in 2022 and worked very well. I’m satisfied with it.# 2. DEVICE. This type of conventional pulse oximeter [ PO ], based on light pulses from red and near-IR LEDs used in a transmission configuration, has been adopted as a routine non-invasive, indirect method for estimating the fractional oxygen saturation, SpO2, which indicates how much functional hemoglobin is bound to oxygen compared to how much of it is unbound. It is established technology, so the conventional POs, despite their range of prices, are nearly identical in function, and, if reasonably well designed, provide similar data. Not only higher prices do not necessarily translate into higher accuracy, but also a manufacturer’s claim that its own signal processing method (DSP, SET, etc) was found to be better in a given clinical study is often negated by other study results. A good rule of thumb in selecting a PO is to search if its model is indeed listed as cleared in the FDA’s “510(K) Premarket Notification” database, which requires data submission to FDA to demonstrate that the device is safe and effective.# 3. SOURCE. This device is the model A310 (and not A310L, as still stated in the Product Description section of this page) of the OEM manufacturer Aeon Technology Co. Ltd. (Shenzhen, China). The A310 available here is distributed by Amemo Inc. (Milpitas, CA), and sold by the storefront of the Tianyi Star Aviation Technology Co. Ltd. (Beijing, China). The seller’s claim in a reply of the Q&A section, that they “recently discovered that other companies sell this product” is a non-sense sales pitch as they, like the other retailers of the OEM A310, buy it from Aeon Technology.# 4. VALIDATION. The A310 is FDA approved. Under the orange silicone cover of the base it has a sticker with the serial number, and a “CE 0123” approval mark showing that its CE mark (assuring conformity with EU’s health and safety protection standards) is certified by the German company Tüv Süd, in whose database the Aeon’s certificates can be found. (This has validity value, since in March 2022, 11 of 15 POs, bought from Amazon and other online platforms, and tested by the UK’s consumer website “Which?” failed to comply with the CE regulations.)# 5. SPECS. The device measures SpO2, heart rate [ PR ], and the so-called perfusion index [ PI ], the ratio of pulsatile to non-pulsatile blood flow. Be aware that the specs in the Product Description section of this page, at the time of this update still do **not** conform to those in the A310 user manual (v.2 March 2020) or the 510(k) application to the FDA, particularly in SpO2% accuracy. The device has the following specs — Display Range: SpO2 35-100%; PR 30-250 bpm; PI 0-20 % (can reach ca. 30% during unstable initial phase) / Accuracy: ±3% for SpO2% between 70 and 100 (unspecified if less); ±1 bpm PR; ±0.1% for PI% of 0 to 1 and ±1% for PI% of 1 to 20 / Resolution: 1% SpO2; 1 bpm PR; 0.1% PI.# 6. ACCURACY. PO manufacturers typically claim an accuracy in the ±1 to ±3 range, which is a laboratory estimate using the root mean square error. But that is a statistic –often referred to as A(rms)– based on the standard deviation of differences between simultaneously measured SpO2 data and directly-read arterial data in healthy subjects, combining data dispersion and offset under highly controlled conditions. Of course, that does not happen in at-home measurements, which is why claims of high accuracy are meaningless for non clinical or lab use. Given the 95 % or higher oxygenation of arterial blood in healthy people, their SpO2% values can be expected within the 93 to 100 range because of the associated errors of the PO technique as well as the normal variation of arterial oxygenation in a single subject and among subjects.# 7. PRECISON. In addition to how close is a PO reading to the value in arterial blood (i.e., accuracy), one needs to consider how close to one another are repeated readings (i.e., precision) — keep in mind the latter is independent of the former. Repeatability differences are evident in my attached figure ploting SpO2% [top] and PI% [bottom] data collected every 5 minutes from my left thumb (after 30 seconds from inserting the finger and turning on the device); in each plot, the respective mean value is shown by a solid line, and the standard deviation limits by dotted lines. While the sample is only 16 repetitions, the data suggest a repeatability of ±2% or less. Always repeat at-home PO measurements — do not miss the oximetric forest for the trees.# 8. MEASURING ISSUES. (a) Selecting a routine target finger — There is published evidence that oximetry provides different percentages in the same person depending on the selected finger. A small study of right-hand dominant, healthy subjects not wearing nail polish concluded that the right thumb and middle finger yielded the statistically highest SpO2. However, you ought to determine your best finger for PO, as this can vary; I have mixed handedness and my left thumb consistently yields the highest values, followed by the right one and the middle finger of both hands. This is shown in my other attached figure, where after normal full (rather than deep) breaths over 30 seconds, the SpO2 readings were taken 15 and 30 seconds after turning on the device — the fingers were measured in a non-sequential manner with a 2-minute resting period between tests.(b) Measuring time — SpO2 readings can vary initially till the device becomes relatively stable, typically within the first minute. Use the plethysmograph (the yellow vertical display on the screen’s right margin) as a guide for accepting SpO2% data once the waveforms are distinctly formed and their amplitude is consistent (in this condition, the PI% should be higher than 1, rather than 0.2). This is likely the only advantage, unless you are a physician or trained nurse, of having a waveform display of how blood volume changes with heart beats. Disregard the recommendation of Amemo in this webpage of “press the operating button, and then wait. Within 10 seconds, you’ll have an accurate reading of you SpO2 levels and pulse rate.” That is FALSE. It takes at least some 10 to 15 seconds for all three measurements to appear in the display (PI is the first and SpO2 the last), and then readings begin to stabilize at least another 10 to 15 seconds later.(c). External error sources — POs yield inaccurate data under a number of conditions. The main known causes are motion artifacts (hand movement, PO slippage), cold fingers, anemia, direct sunlight or bright ambient lights, mechanical-force pulsations from nearby arteries, pulsatile variations of tissue thickness in the light path other than in the arteries, nail polish, and some degrees of skin pigmentation. It is a long list and you should run a search to see if there is a type of error that may systematically affect PO readings in your case.___

    Helpful(0) Unhelpful(0)You have already voted this
  3. Logan

    This works exactly as it should and I compared it to a hospital-grade pulse oximeter setup.
    The title says it all – But keep reading if you want more details.I wore this at the same time I was in the hospital using their setup. The numbers were within one or two points of each other constantly. This is definitely a great option if you’re monitoring health at home, whether you’re doing it yourself or if you’re an in-home nurse monitoring patients’ cardiovascular situation.The device came with batteries that were okay, but should probably be replaced with a higher quality set for longevity; The batteries that came with it lasted for about 3 months. I replaced them with a quality brand name set and I haven’t had to touch them since and that’s after nearly 3 years of usage. It uses 2x standard AAA batteries, so they are highly available and it’s easy to keep a pair of batteries on standby just in case.In summary, accurate readings, great battery life with quality batteries, and a nice compact design with a silicone protective and sanitary cover.I’m glad I spent money on this, and my cardiologist has been happy to see continuous monitoring and logging of my health.Thanks for reading – I don’t post often, but when reflecting about how often I use this and how effective it’s been, I felt like it was worth giving a shout out to its quality. Have a great and healthy day!

    Helpful(0) Unhelpful(0)You have already voted this
  4. C G

    Just as advertised
    I got the order next day, the unit is very easy to use and the display numbers are a good size. The read out depends on the personal activity but I will say it is accurate for our daily routine and test.The batteries have half life as shown in the power lever of the unit. It is light weight and easy to carry with you. I would recommend the unit for the features and the cost, it provides a good service compare to units of similar price.

    Helpful(0) Unhelpful(0)You have already voted this
  5. Somer

    Great Monitor!
    I think this is an excellent monitor for the price. It seems very accurate, it stays on my finger really well, and it’s easy to read. I really love the design and the battery holds up really well also. I also love how easy it is to store it.

    Helpful(0) Unhelpful(0)You have already voted this
  6. Tom from Florida

    Fast, well built, good protective case
    This works great and seems more accurate than my previous one. Much faster at getting scores and it has a rubber case for protection and an outer Velcro case with carry strap. Very good!

    Helpful(0) Unhelpful(0)You have already voted this
  7. Michael W.

    Must have in any home. This particular Pulse Ox is Awesome
    I am normally 94% Oxygen Saturation. This device measures that correctly. So, technically, a poorly designed device could read, say, 2% high… someone at 98 or 99 or 100% would read 100%… or 3% low. Because I normally read 94% and this reads 94% (not 95% or 96%… or maybe 93% or 92%) I would have to say that this one is spot-on! This is a cheap device that I think everyone should have in their home. If you get sick, especially elderly or others in distress, you can now call your doctor if your readings are lower than normal, or consider going to the ER (or calling 911) if your O2 sats are 89% or less. In my case, I was 94% before shoulder surgery (normal for me and no concerns by the doctors). They accidentally paralyzed my diaphragm with the nerve block and, with my O2 sats at 88%, I was admitted to the ER and then overnight until I was no longer hypoxic (as the nerve block wore off, my O2 sats returned to 94%… normal for me)

    Helpful(0) Unhelpful(0)You have already voted this
  8. Trent Heidtke

    Sunlight Readable
    Great product at a more than fair price. Love the ability to read the indicator in sunlight instead of having to hunt for shade. Seems to be accurate and is straightforward to use. All in all a super product and would buy again. Final note, I am a pilot and spend a lot of time here in AZ at 10.5 or higher altitudes and this tool is great for letting me know whether to strap on the O2 in flight or not.

    Helpful(0) Unhelpful(0)You have already voted this

    Add a review

    Your email address will not be published. Required fields are marked *

    56 − = 49
    Powered by MathCaptcha

    Pulse Oximeter,OLED Display Oxygen Monitor Fingertip,Blood Oxygen Saturation Monitor(SpO2) with Carrying Case,Silicone Cover
    Pulse Oximeter,OLED Display Oxygen Monitor Fingertip,Blood Oxygen Saturation Monitor(SpO2) with Carrying Case,Silicone Cover

    $29.99

    Fit N Fresh Co – Elevate Your Health & Fitness Lifestyle
    Logo
    Compare items
    • Total (0)
    Compare
    0
    Shopping cart